Journal cover Journal topic
Climate of the Past An interactive open-access journal of the European Geosciences Union
https://doi.org/10.5194/cp-2017-149
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 4.0 License.
Research article
29 Nov 2017
Review status
This discussion paper is a preprint. It is a manuscript under review for the journal Climate of the Past (CP).
Particle shape accounts for instrumental discrepancy in ice core dust size distributions
Marius Folden Simonsen1, Llorenç Cremonesi2, Giovanni Baccolo4, Samuel Bosch1, Barbara Delmonte4, Tobias Erhardt3, Helle Astrid Kjær1, Marco Potenza2, Anders Svensson1, and Paul Vallelonga1 1Centre for Ice and Climate, Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark
2Department of Physics, University of Milan and National Institute for Nuclear Physics (INFN), Via Celoria 16, I20133 Milan, Italy
3Climate and Environmental Physics, Physics Institute & Oeschger Centre for Climate Change Research, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
4Department of Earth and Environmental Sciences, University Milano-Bicocca, Piazza della Scienza 1, I20126 Milan, Italy
Abstract. The Klotz Abakus laser sensor and the Coulter Counter are both used for measuring the size distribution of insoluble mineral dust particles in ice cores. While the Coulter Counter measures particle volume accurately, the equivalent Abakus instrument measurement deviates substantially from the Coulter Counter depending on the type of sample. We show that the difference between the Abakus and the Coulter Counter measurements is mainly caused by the irregular shape of dust particles in ice core samples. The irregular shape leads means that the calibration routine based on standard spheres must be adjusted. This new calibration routine gives an increased accuracy on Abakus measurements, which may improve future ice core record intercomparisons. We derived an analytical model for extracting the aspect ratio of dust particles from the difference between Abakus and Coulter Counter data. For verification, we measured the aspect ratio of the same samples directly using a Single Particle Extinction and Scattering Instrument. The results demonstrate that the model is accurate enough to discern between samples of aspect ratio 0.3 and 0.4 using only the comparison of Abakus and Coulter Counter data.

Citation: Simonsen, M. F., Cremonesi, L., Baccolo, G., Bosch, S., Delmonte, B., Erhardt, T., Kjær, H. A., Potenza, M., Svensson, A., and Vallelonga, P.: Particle shape accounts for instrumental discrepancy in ice core dust size distributions, Clim. Past Discuss., https://doi.org/10.5194/cp-2017-149, in review, 2017.
Marius Folden Simonsen et al.
Marius Folden Simonsen et al.
Marius Folden Simonsen et al.

Viewed

Total article views: 185 (including HTML, PDF, and XML)

HTML PDF XML Total BibTeX EndNote
145 38 2 185 2 1

Views and downloads (calculated since 29 Nov 2017)

Cumulative views and downloads (calculated since 29 Nov 2017)

Viewed (geographical distribution)

Total article views: 185 (including HTML, PDF, and XML)

Thereof 183 with geography defined and 2 with unknown origin.

Country # Views %
  • 1

Saved

Discussed

Latest update: 13 Dec 2017
Publications Copernicus
Download
Short summary
Ice core dust size distributions is today more often measured by an Abakus laser sensor than by the more technically demanding but also very accurate Coulter Counter. However, Abakus measurements consistently give larger particle sizes. We show here that this bias exists because the particles are flat and elongated. Correcting for this gives more accurate Abakus measurements. Furthermore, the shape of the particles can be extracted from a combination of Coulter Counter and Abakus measurements.
Ice core dust size distributions is today more often measured by an Abakus laser sensor than by...
Share